Publicación: Digitalization of a calibration laboratory: Batch calibration
| dc.contributor.author | Perez Sanz, Fernando | |
| dc.contributor.author | Larroca Sanz, Rebeca | |
| dc.contributor.author | Mohíno Herranz, Inmaculada | |
| dc.contributor.author | García Gallegos, Jaime | |
| dc.contributor.author | Vicente Mussons, Tomás | |
| dc.contributor.author | Benyon Puig, Robert | |
| dc.date.accessioned | 2025-12-18T09:06:45Z | |
| dc.date.available | 2025-12-18T09:06:45Z | |
| dc.date.issued | 2024-12-22 | |
| dc.description | We thank CDTI for funding the CDTI IDI-20170265 project “Development of a software application for the automation of the analysis of the calculations of the tests and measurements with metrological traceability” and the team at Whitestone Technology and INTA, whose dedication and effort made it possible to develop the software tool used in this work. CDTI is a Business Public Entity under the Ministry of Science, Innovation and Universities that promotes innovation and technological development of Spanish companies. | |
| dc.description.abstract | The Metrology and Calibration Centre (CMC) at the National Institute of Aerospace Technology (INTA) has introduced an innovative tool designed to enhance the efficiency and effectiveness of calibration processes within its facilities. This cutting-edge software enables technicians to conduct multiple calibrations simultaneously, provided the requisite experimental setup is in place. Developed with a focus on streamlining the entire calibration workflow, from data acquisition to certificate issuance, the software ensures compliance with the ISO/IEC 17025 standard. Through rigorous testing, the CMC verified the software's performance using devices employed for monitoring ambient conditions (temperature and humidity) across various INTA test laboratories. Notably, these devices underwent batch calibration in groups of six, resulting in a sixfold reduction in experimentation time. Although the associated paperwork was reduced, the necessity to maintain traceability and issue individual calibration certificates for each device offsets the time savings. | |
| dc.description.peerreviewed | Peerreview | |
| dc.identifier.citation | Measurement: Sensors 38: 101498 | |
| dc.identifier.doi | 10.1016/j.measen.2024.101498 | |
| dc.identifier.issn | 2665-9174 | |
| dc.identifier.other | https://www.sciencedirect.com/science/article/pii/S2665917424004744 | |
| dc.identifier.uri | https://hdl.handle.net/20.500.12666/1603 | |
| dc.language.iso | eng | |
| dc.publisher | Elsevier | |
| dc.relation.isreferencedby | [1] WHITESTONE Calibry website, Online [accessed 18/04/2024] https://www.white stonetechnology.com. [2] International Standard Organization, General Requirements for the Competence of Testing and Calibration Laboratories (ISO 17025:2017), 2017. [3] International Standard Organization, Conformity Assessment — General Requirements for the Competence of Proficiency Testing Providers (ISO 17043:2023), 2023. [4] F. Conde García, M.R. Larroca Sanz, T. Vicente Mussons, J. García Gallegos, R. Benyon Puig, Calibracion ´ Automatizada de Grandes Lotes de Sensores de Temperatura y Humedad con Mínima Incertidumbre, VII Congreso Espanol ˜ de metrología (27-29 Sept. 2022). Online, https://congresodemetrologia.cem.es/do cumentos/R_SP2-R34-P_p.pdf. (Accessed 18 April 2024). [5] British standards, Humidity. Terms, Definitions and Formulae (BS 1339-1:2002), 2002. [6] L. Rivas Hidalgo, A. Torrubia Inigo, ˜ P. Hernandez Matas, T. Vicente Mussons, Calibracion ´ de sensores de humedad relativa y temperatura por comparacion, ´ in: INTA’a Humidity Laboratory Internal Procedure, 2018. [7] IPM, IEC, IFCC, ILAC, ISO, IUPAC, IUPAP, and OIML, Evaluation of measurement data — Guide to the expression of uncertainty in measurement. Joint Committee for Guides in Metrology, JCGM 100 (2008). | |
| dc.rights | Attribution-NonCommercial-ShareAlike 4.0 International | en |
| dc.rights.accessRights | info:eu-repo/semantics/openAccess | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-sa/4.0/ | |
| dc.subject | Digitalization | |
| dc.subject | Traceability | |
| dc.subject | Calibration | |
| dc.subject | Simultaneous calibration | |
| dc.title | Digitalization of a calibration laboratory: Batch calibration | |
| dc.type | info:eu-repo/semantics/article | |
| dc.type.coar | http://purl.org/coar/resource_type/c_2df8fbb1 | |
| dc.type.hasVersion | info:eu-repo/semantics/publishedVersion | |
| dspace.entity.type | Publication | |
| relation.isAuthorOfPublication | 336476e8-afa5-4909-b07e-aecd668ca031 | |
| relation.isAuthorOfPublication | 76d131d2-cd15-4863-bec5-0cfe59ac5913 | |
| relation.isAuthorOfPublication | 524643fd-c895-4ebc-a7b9-4703638710fb | |
| relation.isAuthorOfPublication | ee424b53-4a7e-41c2-a411-d60c24243c9e | |
| relation.isAuthorOfPublication.latestForDiscovery | 336476e8-afa5-4909-b07e-aecd668ca031 |
Archivos
Bloque original
1 - 1 de 1
Cargando...
- Nombre:
- Digitalization of a calibration laboratory - batch calibration.pdf
- Tamaño:
- 871.5 KB
- Formato:
- Adobe Portable Document Format
Bloque de licencias
1 - 1 de 1
No hay miniatura disponible
- Nombre:
- license.txt
- Tamaño:
- 4.77 KB
- Formato:
- Item-specific license agreed upon to submission
- Descripción: